Home›Repair guides›Cummins/Onan›Remote Mounting Control Box

Cummins/Onan — Remote Mounting Control Box

Installation

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan HDKA, Cummins/Onan HDKAL/HDKAS engine

Procedure

  1. Remove the DC control box cover and unscrew the bolts from the four vibration isolators that support the control box.
  2. Remove the control box and isolators from the studs on the mounting surface.
  3. Drill holes of the appropriate size and place the box in the new position.
  4. Make sure there is enough room to insert and remove the wiring harness connector plugs at the back of the control box.
  5. If remounting on isolators, mount the toothed washers under the vibration isolators to prevent rotation.

Specs & values

  • Ambient temperature at new location must not exceed 160°F (71°C)

Full service-parts list: Cummins/Onan HDKA →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.