Cummins/Onan — Recommended Starting Technique Using Fleetguard Starting Aid
Operation
From a Cummins/Onan operator's manual covering: KT-1150, KT-1150-C450, KT-1150-P450, KT-2300, KT-2300-C900, KT-2300-P900, KTA-1150, KTA-1150-C525, KTA-1150-C600, KTA-1150-P600, KTA-2300, KTA-2300-C1050…. Check it applies to your exact model before use.
Browse Cummins/Onan generators & specs →
Before you start
- Never handle starting fluid near an open flame. Never use with preheater or flame thrower equipment. Do not breathe fumes.
- Fuel oil or volatile fuel cold starting aids must not be used in underground mine or tunnel operations.
Procedure
- Set throttle for idle.
- Disengage driven unit or make sure gears are in neutral.
- Open manual or electric fuel shut-down valve, whichever used.
- Engage starter and while cranking, apply metered amounts of starting fluid until engine idles smoothly.
Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.