Cummins/Onan — Reactors Testing - Method D (Ohmmeter)

Testing & diagnosis

From a Cummins/Onan service manual covering: 02SX1N1A, 04SX1N, 04SX1N1A, 04SX1N1B, 04SX1N2B, 04SX1N3B, 04SX1N4B, 06SX1N, 06SX1N1A, 06SX1N1B, 06SX1N2B, 06SX1N3B…. Check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Select resistance range on meter to resistance specified in Table 3 for given rectifier model.
  2. Isolate one gate winding by disconnecting either end of gate winding G1-G2; e.g., disconnect G1 at E2.
  3. Measure resistance in gate winding across G1-G2.
  4. Isolate control winding by disconnecting either lead C1 or C2 from terminal strip. Measure resistance across C1-C2.
  5. Connect one meter lead to disconnected gate winding lead and other to disconnected control winding lead; check continuity.
  6. Good if resistance within ±20 percent of Table 3 value and no continuity between control and gate windings.
  7. Defective if open circuit in gate or control winding or continuity between windings; replace reactor.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • resistance within ±20 percent of Table 3 value

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.