Home›Repair guides›Cummins/Onan›Raw Water Pickup Test

Cummins/Onan — Raw Water Pickup Test

Testing & diagnosis · Raw water cooling system

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan MDKAV, Cummins/Onan MDKAW, Cummins/Onan MDKAZ, Cummins/Onan MDKB, Kubota D1105 engine, Kubota V1305 engine, Kubota V1505 engine, Kubota V1903B engine, Kubota V2203B engine, Kubota V2803B engine

Before you start

  • Be ready to close the sea cock and catch water that spills.

Procedure

  1. Load the boat fully for sea trials, shut down the genset, and disconnect the raw water pickup hose from the genset bulkhead fitting.
  2. Raise and lower the end of the hose; the water line is where water just begins to spill.
  3. Mark the highest water line observed while operating the boat throughout its speed range, and mark the line while docked.
  4. If either water line is within 6 inches (152 mm) of the engine exhaust-water mixer, install a siphon-break device.

Specs & values

  • 6 in (152 mm) minimum separation from exhaust-water mixer

Full service-parts list: Cummins/Onan MDKAV →, Cummins/Onan MDKAW →, Cummins/Onan MDKAZ →, Cummins/Onan MDKB →, Kubota D1105 engine →, Kubota V1305 engine →, Kubota V1903B engine →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.