HomeRepair guidesProper engine break-in is necessary for top performance.

Cummins/Onan — Proper engine break-in is necessary for top performance.

For these Cummins/Onan models: EGMBT, EGMBT (P4500), EGMBU, EGMBU (P5000E), EGMBU (P5000e), P24500 (Spec A), P5000e (Spec A).

Applies to: Cummins Onan Egmbt, Cummins Onan Egmbu

Procedure

  1. 1. Operate the generator set as it is intended to be operated. However, for the first 1-1/2 hours, if possible, run the generator set at 50 percent capacity, occasionally operating at full power for brief periods. Avoid prolonged low-power operation during break-in.
  2. 2. Make sure the engine has oil of the proper viscosity for the ambient temperature (see Engine Oil Recommendations).
  3. 3. Check the oil level twice a day or after every 4 hours of operation during the first 20 hours of operation.

Source: manual:914-0508 Onan EGMBT P24500 EGMBU P5000e (spec A) Portable Genset Service manual (10-2009).pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.