Home›Repair guides›Cummins/Onan›Preparation for storage (6 months or longer)

Cummins/Onan — Preparation for storage (6 months or longer)

Maintenance · Generator set

From a Cummins/Onan operator's manual covering: PX4800, RGX2900, RGX3600. Check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Before you start

  • NEVER USE WATER TO CLEAN GENERATOR!

Procedure

  1. Drain fuel from the fuel tank carefully by disconnecting the fuel line.
  2. Remove the carburetor float chamber and also drain the carburetor.
  3. Change engine oil.
  4. Check for loose bolts and screws, tighten them if necessary.
  5. Clean the generator thoroughly with oiled cloth; spray with preservative if available.
  6. Pull the starter handle until resistance is felt, leaving the handle in that position.
  7. Store the generator in a well ventilated, low humidity area.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.