Cummins/Onan — Preliminary adjustment: Before adjusting the governor
For these Cummins/Onan models: BGD, NHD.
Applies to: Cummins Onan Bgd
Procedure
- Loosen the jam nut at the ball joint end of the gover-
- Disconnect the governor rod from the throttle lever.
- With the carburetor throttle fully open and the gov-
- Turn the governor rod in (shorter) one full turn.
- Reconnect the governor rod and retighten the jam
- Run the genset at least 15 minutes at 50% to 75% of
- Remove the load and let the set stabilize 10 to 15
- Read the gensetfrequency. With no load,frequency
- Turn the speed nut until the no-load frequency is
- - 50 Hz (38 - 42 Hz for 50 Hz sets).
- Slowly turn the idle stop screw in to increase the
- Turn the speed nut in until the no-load frequency is
- - 63 Hz (51.5 - 52.5 Hz for 50 Hz sets).
- Connect rated load.
- Check frequency with rated load connected.
- Check output voltage. Service the generator (Sec-
- 5 Hz for 50 Hz sets), and check droop again.
- Hzsets), turn the sensitivity adjustment screw
- Check governor response under no load, 1 14 load,
- load, 314 load and rated load. If the governor
Source: manual:965-0529 Onan BGD NHD (spec A-G) Commercial Genset Service manual (05-1992).pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.