Home›Repair guides›Cummins/Onan›Storing Generator

Cummins/Onan P9500df — Storing Generator

Maintenance

For the Cummins/Onan P9500df, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan P9500df

Before you start

  • Gasoline stored for as little as 60 days can go bad

Procedure

  1. Switch Engine Switch to STOP so generator does not draw power from battery
  2. Clean the generator
  3. Drain all gasoline from fuel tank as best as possible
  4. With fuel shut off valve open, start engine and run until remaining gasoline in lines/carburetor is consumed and engine shuts off
  5. Close fuel shut off valve
  6. Drain remaining gas in carburetor float bowl
  7. Change the oil
  8. Remove spark plug, place about 1 tablespoon of oil in spark plug opening, pull recoil handle several times to distribute oil
  9. Replace spark plug
  10. Move generator to a clean, dry place for storage

Full service-parts list: Cummins/Onan P9500df →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →