Cummins/Onan P4500 — Electric Starting

Operation · Engine

For the Cummins/Onan P4500, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan P4500

Before you start

  • Do not refill gas while generator is running

Procedure

  1. Make sure nothing is plugged into power outlets.
  2. Remove battery access cover and connect battery leads.
  3. Make sure circuit breakers are properly set to operating position.
  4. Turn Fuel Control Switch to ON position.
  5. Switch Engine Control Switch to RUN.
  6. Push and hold engine start button for 1 second and release.
  7. For remote start hold START button on wireless remote for 1 second and release.
  8. Plug in electronic devices.

Full service-parts list: Cummins/Onan P4500 →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →