Cummins/Onan P2400 / P3500 — Storing the Generator Set (Out-of-Service Protection)

Maintenance

For the Cummins/Onan P2400 / P3500, from the Cummins/Onan service manual.

Browse Cummins/Onan generators & specs →

Before you start

  • Fuel additives can cause a risk of personal injury. Read and follow the manufacturer's instructions.

Procedure

  1. Add a fuel preservative and stabilizer to the fuel tank, or let the generator set run out of fuel.
  2. Shut the fuel valve and drain the carburetor bowl.
  3. Remove the spark plug; squirt one tablespoon (about 30 cm3) of clean engine oil into the spark plug hole; turn the engine over several revolutions; replace the spark plug; pull the recoil starter hand
  4. Change engine oil and attach a tag indicating the viscosity of oil used.
  5. Store the generator set in a dry, protected area.

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.