Home›Repair guides›Cummins/Onan›Reconnecting and Reclamping the Choke Cable (Manual Choke)

Cummins/Onan P218 / P220 — Reconnecting and Reclamping the Choke Cable (Manual Choke)

Adjustments

For the Cummins/Onan P218 / P220, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan P218, Cummins/Onan P220

Before you start

  • Accidental starting of the engine can result in severe personal injury or death. Always disconnect the spark plug and battery (negative cable) before resetting the engine control cables.

Procedure

  1. Stop the engine and disconnect the spark plugs and, if so equipped, the battery (negative cable).
  2. Push the equipment choke knob to the full-open choke position.
  3. Connect the choke cable to the choke lever (hook in or clamp with screw in swivel).
  4. Pull the slack out of the cable and clamp it.
  5. Check for smooth movement and full travel of the choke knob; remove air cleaner element to verify choke plate opens and closes fully.
  6. Reassemble the air cleaner and reconnect the spark plug and battery.

Full service-parts list: Cummins/Onan P218 →, Cummins/Onan P220 →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →