Home›Repair guides›Cummins/Onan›AC output measuring

Cummins/Onan P1700i — AC output measuring

Testing & diagnosis · Generator

For the Cummins/Onan P1700i, from the Cummins/Onan service manual.

Applies to: Cummins/Onan P1700i, Cummins/Onan EH09-2D engine

Procedure

  1. Use a circuit with a load such as a hot plate or lamp with a power factor of 1.0.
  2. Adjust the load and rpm.
  3. Check that the voltage range is as specified at the rated amperage and rated rpm.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 120V/60Hz: 117-126 V; 230V/50Hz: 225-242 V; 240V/50Hz: 235-252 V

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →