Cummins/Onan OT-A-4060A / OT-C-10050C — Setting the Exerciser Clock Time of Day
Operation
For the Cummins/Onan OT-A-4060A / OT-C-10050C, from the Cummins/Onan service manual.
Browse Cummins/Onan generators & specs →
Procedure
- Press the R button with a ball point pen to reset all memory when performing installation and setup.
- Press the clock button.
- Press the h button to set the hour of the day (24-hour military time).
- Press the m button to set the minutes of the hour.
- Press the 1-7 button to advance the indicator bar over the desired day number (1 represents Sunday).
- Press the Pr button to enter the time.
Tools required
- Ball point pen Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- 7-day, 24-hour clock; up to ten start/stop programs (exercise cycles)
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.