Cummins/Onan Onan P4500i / P4500 — Starting the Generator

Operation

For the Cummins/Onan Onan P4500i / P4500, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan Onan P4500i, Cummins/Onan P4500

Procedure

  1. Place the generator in a safe, appropriate location.
  2. Unplug all loads.
  3. Ensure the ECO mode switch is in the OFF position.
  4. Check oil and fuel levels.
  5. Turn the fuel switch to the ON position.
  6. Push the battery switch to the ON position.
  7. For recoil start: remove the engine service cover, set the choke to on/cold start, then pull the recoil handle.
  8. For remote start: push and hold the ON button on the key fob for two seconds.
  9. For electric start: push and hold the engine START/STOP button for two seconds.
  10. After the engine starts and stabilizes (~5 seconds), move the choke to off/warm start.
  11. When the OUTPUT READY LED illuminates, connect loads to the receptacles.
  12. Connect and start the largest device; allow output to stabilize; repeat for each load.

Full service-parts list: Cummins/Onan Onan P4500i →, Cummins/Onan P4500 →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →