Home›Repair guides›Cummins/Onan›Parallel Operation

Cummins/Onan Onan P4500i Inverter / P4500 — Parallel Operation

Installation · Parallel kit

For the Cummins/Onan Onan P4500i Inverter / P4500, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan P4500

Before you start

  • NEVER connect or disconnect the parallel cord leads when a generator is running.
  • DO NOT connect two red leads or two black leads into the same generator.

Procedure

  1. Make sure both generator battery switches and ECO MODE switches are in the OFF position.
  2. Connect the black and red parallel cable leads to the black parallel ports; black lead to left port, red lead to right port.
  3. Connect the green ground lead to the ground terminal on each generator and tighten the nut.
  4. Start one generator and wait until the OUTPUT READY LED illuminates.
  5. Start the second generator and wait until the OUTPUT READY LED illuminates before connecting a load.
  6. Connect additional loads as described in the Power Management section.
  7. Unplug all loads before stopping the generators.

Specs & values

Full service-parts list: Cummins/Onan P4500 →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.