Operation · OT III Transfer Switch

From a Cummins/Onan service manual — check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Before you start

  • AC power within the cabinet and the rear side of the cabinet door presents a shock hazard that can cause severe personal injury or death. Remove all AC power before manual operation if possible.
  • Automatic transfer switch operation results in rapid movement of the manual operator handles and presents a hazard of severe personal injury. Keep hands clear of handles when switching back to automatic operation.

Procedure

  1. Open the cabinet door of the automatic transfer switch.
  2. Move the Motor Disconnect switch to the Off position.
  3. Transfer to emergency: pull the upper manual operator handle down, then push the lower handle down.
  4. Retransfer to normal: pull the lower manual operator handle up, then push the upper handle up.
  5. Move the Motor Disconnect switch back to the Auto position (switch transfers load to the active source; Normal source if both available).
  6. Close the cabinet door.

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.