Home›Repair guides›Cummins/Onan›Purging Fuel System (BGEL Liquid LPG)

Cummins/Onan M-1600-2 — Purging Fuel System (BGEL Liquid LPG)

Maintenance

For the Cummins/Onan M-1600-2, from the Cummins/Onan operator's manual.

Browse Cummins/Onan generators & specs →

Before you start

  • Liquid LP gas presents hazard of fire or explosion
  • Eliminate all sources of ignition before purging

Procedure

  1. Close shutoff valve at the fuel tank
  2. Start generator set and run until it runs out of fuel
  3. Crank engine a few times after it stops to completely purge fuel
  4. Move RV to well-ventilated location away from ignition sources
  5. Remove vehicle negative battery ground cable and generator set negative ground cable
  6. Close fuel shutoff valves at tank and at each appliance
  7. Slightly open flexible fuel line at solenoid valve to allow gas to escape slowly
  8. Disconnect fuel supply hose from carburetor and hold clear of set; press primer button until no gas escapes, then reconnect

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.