Cummins/Onan M-1600-2 — Lowering the Under-Floor Mount Generator Set

Maintenance

For the Cummins/Onan M-1600-2, from the Cummins/Onan operator's manual.

Browse Cummins/Onan generators & specs →

Before you start

  • Use a floor jack or other device to control weight; do not lower by hand
  • If leaving set lowered more than thirty minutes, first drain the oil

Procedure

  1. Park RV on as level a surface as possible
  2. Put vehicle in park, lock brakes, remove ignition key; ensure no one moves vehicle
  3. Disconnect both battery cables at generator set starting battery; open access door
  4. Separate exhaust system near generator set if connected to under-structure
  5. Check electrical connections and fuel line for sufficient slack
  6. Position floor jack under reinforcement ribs of drip tray
  7. Raise jack until it contacts drip tray and apply slight upward pressure
  8. Remove four bolts and front support bracket; slowly lower jack, allowing it to roll as set swings down; block drip tray before removing jack

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Refer to SPECIFICATIONS section for unit weight

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.