Home›Repair guides›Cummins/Onan›LPG Vaporizer Adjustment

Cummins/Onan — LPG Vaporizer Adjustment

Adjustments · Fuel System

From a Cummins/Onan service manual — check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Place vaporizer in vise or suitable clamp.
  2. Attach air hose at approximately 75 psi to inlet.
  3. Attach pressure gauge capable of reading over 7 psi to outlet.
  4. Back off adjusting screw until only one or two threads engaged.
  5. Apply air pressure.
  6. Turn pressure adjusting screw in slowly until gauge reads 7 psi.
  7. Tighten lock nut and remove gauge and air line.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Working pressure: 7 psi (48.3 kPa)

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.