Home›Repair guides›Cummins/Onan›LPG Supply Pressure Adjustment

Cummins/Onan — LPG Supply Pressure Adjustment

Adjustments · LPG supply regulator

From a Cummins/Onan service manual — check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Before you start

  • LPG is flammable and explosive and can cause asphyxiation.

Procedure

  1. Close the gas shutoff valve(s) at the LPG container(s).
  2. Remove the 1/8 inch pipe plug from the regulator test port and connect a manometer.
  3. Open the LPG container shutoff valve and try starting the genset.
  4. While the genset is running, adjust the LPG supply pressure regulator to 11 inches (279 mm) WC.
  5. If the genset will not start, jumper the fuel solenoid to the battery cable connections so it stays open.
  6. Check LPG supply pressure under full load.
  7. Disconnect any jumpers and tighten the pressure test port plug.

Tools required

  • Manometer (14 inch / 350 mm WC range) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • LPG supply pressure 9-13 inches (229-330 mm) WC
  • Adjust to 11 inches (279 mm) WC

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.