Cummins/Onan JWC4-10S-3 — Starting the Power Unit Electrically

Operation

For the Cummins/Onan JWC4-10S-3, from the Cummins/Onan service manual.

Browse Cummins/Onan generators & specs →

Before you start

  • If START button is released before oil pressure builds, the engine will stop.

Procedure

  1. Make sure CIRCUIT BREAKER is in OFF position.
  2. Make sure MANUAL START-REMOTE START switch is in REMOTE START position.
  3. Press START button firmly until engine starts and oil pressure builds, not more than 10 or 15 seconds.
  4. If it fails to start, wait 10 seconds and repeat.
  5. After engine starts, check oil pressure gauge and control panel gauges.
  6. Throw CIRCUIT BREAKER to ON to connect load.

Specs & values

  • Oil pressure about 22 pounds
  • Water temperature about 175 F
  • Battery charge rate 2 to 10 amperes

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.