Home›Repair guides›Cummins/Onan›Installation of Readi-Pull Starter

Cummins/Onan — Installation of Readi-Pull Starter

Installation · Readi-Pull manual starter

From a Cummins/Onan service manual — check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Before you start

  • The recoil spring may unwind and cause injury if let fly wildly when disassembled or reassembled.

Procedure

  1. Install new ratchet wheel against rope sheave with lock washer and flywheel mounting screw.
  2. Install special nuts for mounting starter to blower housing.
  3. Use two bottom blower housing screws to install left and right hand starter mounting brackets; do not tighten.
  4. Install centering pin in starter center screw allowing 3/8 in to protrude.
  5. Center starter over ratchet wheel with centering pin engaged; mount with hex head screw, lock washer and two flat washers per arm.
  6. Tighten mounting screws securely.
  7. Tighten two lower blower housing screws removed earlier.
  8. Loosen four clamp screws and turn starter in mounting ring to adjust direction of pull; tighten securely.

Specs & values

  • Centering pin protrudes 3/8 in

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.