Cummins/Onan GTA14 / GTA14 qi 20 NA — Normal Starting Procedure (Above 0 C [32 F])

Operation · Engine

For the Cummins/Onan GTA14 / GTA14 qi 20 NA, from the Cummins/Onan owner's manual.

Applies to: Cummins/Onan GTA14 qi 20 NA, Cummins/Onan GTA14 engine

Before you start

  • Do not crank engine more than 30 seconds at a time; wait two minutes before recranking
  • Do not idle engine for more than 10 minutes

Procedure

  1. Check lubricating oil and engine coolant levels.
  2. Set throttle for idle speed.
  3. Disengage clutch or open main circuit breaker on genset applications.
  4. Open gas supply shut-off valve.
  5. Return manual reset fuel shut-off valve to open position if equipped.
  6. Push reset button on instrument panel.
  7. Hold in safety switch override and push start button.
  8. Release override when oil pressure shows increase.
  9. Engage clutch and run just above idle to warm coolant.

Specs & values

  • Oil pressure must be indicated within 15 seconds after starting
  • Idle no more than 3 to 5 minutes at 1000 RPM before applying load

Full service-parts list: Cummins/Onan GTA14 qi 20 NA →

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.