Home›Repair guides›Cummins/Onan›Simulate an overspeed condition that causes a fault

Cummins/Onan GST30 G-Drive / QST30 G-Drive — Simulate an overspeed condition that causes a fault

Testing & diagnosis · Fault Simulation - Overspeed tab

For the Cummins/Onan GST30 G-Drive / QST30 G-Drive, from the Cummins/Onan service manual.

Applies to: Cummins/Onan QST30 G-Drive engine

Before you start

  • Fault simulation temporarily overrides the engine's actual fault sensors; exit normally or sensors remain disabled.

Procedure

  1. Adjust the Shutdown Threshold spin box to the desired test point.
  2. Click an up or down arrow to activate Rated Speed Override.
  3. Change speed in 10 RPM increments (auto-sent to ECM), or type a value and click Send.

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.