Home›Repair guides›Cummins/Onan›Starting the engine (manual crank)

Cummins/Onan GS-107-AC — Starting the engine (manual crank)

Operation

For the Cummins/Onan GS-107-AC, from the Cummins/Onan service manual.

Applies to: Hol-Gar GS-107-AC, Cummins/Onan J120-S/967F engine

Procedure

  1. Prime carburetor with fuel pump priming lever about 15 strokes; return lever inward.
  2. Set engine switch in START position.
  3. Set hand choke as required by local temperature.
  4. Engage hand crank with handle at 7 o'clock position.
  5. Pull crank to 12 o'clock with sharp steady pull; remove when engine starts.
  6. Place engine switch in RUN position.
  7. Check oil pressure; it should be at least 20 psi.
  8. Readjust choke as engine warms.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Oil pressure at least 20 psi

Full service-parts list: Hol-Gar GS-107-AC →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.