Home›Repair guides›Cummins/Onan›Governor Sensitivity Adjustment

Cummins/Onan — Governor Sensitivity Adjustment

Adjustments

From a Cummins/Onan service manual — check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Before you start

  • A too-sensitive setting will result in surging speed (hunting).

Procedure

  1. Run engine about 10 minutes to reach normal operating temperature.
  2. Ensure carburetor main load and idle needles are properly adjusted.
  3. Check engine speed with no load and again after connecting full-rated load; speed drop must be within 100 rpm.
  4. To increase sensitivity, move governor spring toward governor shaft.
  5. To decrease sensitivity, move governor spring toward linkage end of governor arm.
  6. Always recheck speed adjustment after sensitivity adjustment.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Speed drop from no-load to full-load must be within 100 rpm.

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.