Home›Repair guides›Cummins/Onan›Generator - Replacement

Cummins/Onan — Generator - Replacement

Repair & overhaul

From a Cummins/Onan service manual — check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Disconnect battery negative cable.
  2. Remove drive belt.
  3. Remove 2 bolts and position the generator aside.
  4. Disconnect electrical connector.
  5. Remove generator.
  6. Install: tighten generator bolts to 25 Nm (18 lb-ft), B+ terminal to 8 Nm (71 lb-in).

Specs & values

  • Generator bolts 25 Nm (18 lb-ft)
  • B+ terminal 8 Nm (71 lb-in)

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →