Home›Repair guides›Cummins/Onan›Generator Ball Bearing Service

Cummins/Onan — Generator Ball Bearing Service

Maintenance

From a Cummins/Onan owner's manual — check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Before you start

  • Be sure that no dirt gets into the bearing.

Procedure

  1. Remove the plate from the housing rear end.
  2. Clean all dirt from around the generator bearing cover and remove the cover and gasket.
  3. Remove the old lubricant from the bearing with a clean finger.
  4. Work about one tablespoon of new ball bearing lubricant into the bearing and remove it again.
  5. Refill the bearing housing about one half full of bearing lubricant, packing it well into the lower half.
  6. Reinstall the bearing cover, using a new gasket if necessary.

Specs & values

  • Each 6 months or 1200 operating hours, whichever occurs first

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.