Cummins/Onan — Gas-Gasoline Conversion

Operation · carburetor

From a Cummins/Onan operator's manual covering: 305CCK, 4CCK, 5CCK. Check it applies to your exact model before use.

Applies to: Cummins/Onan CCK engine

Procedure

  1. Close manual fuel shut-off valve for gas supply.
  2. Open gasoline fuel shut-off valve.
  3. Unscrew carburetor float lock all the way outward to backseat.
  4. Set spark plug gap as given in Table of Clearances.
  5. See that choke is free and works easily.
  6. Start engine in manner described for the engine.

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.