Cummins/Onan — Full power switch operation (dual voltage type, PX4800e)
Operation
From a Cummins/Onan operator's manual covering: PX4800, RGX2900, RGX3600. Check it applies to your exact model before use.
Browse Cummins/Onan generators & specs →
Before you start
- Change the FULL POWER SWITCH after turning the AC circuit breaker to OFF.
Procedure
- Turn the AC circuit breaker to OFF before changing the FULL POWER SWITCH.
- Select the voltage using the FULL POWER SWITCH in accordance with the electrical appliance (TABLE 2).
- Operate in the same way as steps (a) through (d) of the single voltage type.
Specs & values
- 120V: lower voltage receptacle activated at full rated output; higher voltage receptacle N.A.
- 120/240V: lower voltage receptacle activated at half of rated output; higher voltage receptacle activated at full rated output.
- Voltmeter always indicates the lower voltage whenever the FULL POWER SWITCH is set.
Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.