Cummins/Onan — Equalize Charging

Operation · Battery bank (Wet Cell only)

From a Cummins/Onan owner's manual covering: 1.5HJBAA, 2.0HJBAA, 2.5HJBAA, 3.0HJBAA. Check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Before you start

  • Disconnect all DC appliances before equalizing to prevent damage from the high equalize charging voltage.

Procedure

  1. Go to BATT CHARGE RATE to get to the EQUALIZE CHARGE screen. Press EQUAL.
  2. Review the safety pages and press START.
  3. If the batteries are not fully charged, press OK and wait for full charge.
  4. Charging current ramps up to 5 percent of battery bank capacity; equalize voltage 15.5 V is held for 30 minutes and time remaining recalculated.
  5. Press STOP at any time; total charging time, including up to 30 minutes cooling, will not exceed 6 hours.
  6. Batteries must be attended while equalizing; be prepared to stop charging if a cell overheats, overflows, splits or cracks.

Specs & values

  • Equalize voltage 15.5 V
  • Charging current 5 percent of battery bank capacity
  • Total charging time not to exceed 6 hours

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.