Cummins/Onan RBAA — Service Procedure

For the Cummins/Onan RBAA.

Applies to: Cummins Onan Rbaa

Procedure

  1. Remove the fan and hydraulic motor (Fig-
  2. Remove the drive bearing retention ring so that
  3. The generator wrapper has two holes on oppo-
  4. Scribe lines before separating the endbells
  5. Disconnect the field leads from the exciter end-
  6. Remove the four nuts and washers on the sta-
  7. Remove the exciter endbell bracket from the
  8. Tap the exciter endbell free and lift it away.
  9. Lift the stator straight up free of endbell and ro-
  10. Remove the four through bolts.
  11. Remove the air baffle.
  12. Thread an M10 eyebolt into the end of the rotor
  13. Use a puller to remove a defective exciter rotor

Tools required

  • ure 7). Use three M6 screws and a puller to re-
  • 13. Use a puller to remove a defective exciter rotor