Cummins/Onan HDZAA — Installation Manual).
For the Cummins/Onan HDZAA.
Applies to: Cummins Onan Hdzaa
Procedure
- If engine appears to be cooling properly, re-
- f there is a short to ground when the generator
- Check wiring for shorts to ground and repair as
- If the low oil pressure and high oil temperature
- The Operator Panel in the vehicle must be able
- Without power from the PMA auxiliary windings
- Faulty inverter.
- Disconnect the vehicle AC wiring from the gen-
- Check for open wiring, shorts to ground, and
- Check for open wiring to ground and bad
- Check for open wiring, shorts to ground, and
- Check for open wiring, shorts to ground, and
- Check PMA winding connections to the internal
- Replace a faulty inverter.
- 3
- Reduce loads.
- Verify that the inverter heat sink is clean and
- After allowing generator and inverter too cool,
Source: manual:983-0502 Onan HDZAA (spec A-B) Diesel Genset Service manual (06-2010).pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.