Procedure
- Turn the Start Fuel Limit pot fully clockwise and leave it in that position.
- Set the pots initially: Gain mid-position, Stability mid-position, Rated Speed fully counterclockwise.
- If a remote speed pot is used, set it to the fully counterclockwise position.
- Start the set and adjust the Rated Speed pot to obtain 60 Hertz (1800 RPM) or 50 Hertz (1500 RPM); warm up under load.
- Disconnect the load and turn the Gain pot fully clockwise or until unstable, then counterclockwise until stable.
- Adjust Stability as in the previous step.
- Readjust Rated Speed if necessary.
- Observe speed overshoot; turn the Gain pot clockwise slightly to reduce overshoot or the Stability pot counterclockwise if the set oscillates.
Specs & values
- Gain mid-position
- Stability mid-position
- Rated Speed fully counterclockwise
- 60 Hertz (1800 RPM)
- 50 Hertz (1500 RPM)
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.