Home›Repair guides›Cummins/Onan›Start Solenoid Checkout

Cummins/Onan DL3 — Start Solenoid Checkout

Testing & diagnosis · Start solenoid K11

For the Cummins/Onan DL3, from the Cummins/Onan service manual.

Applies to: Cummins/Onan L Series Diesel engine

Procedure

  1. Apply 12-volt battery positive (+) to the K11 coil terminal S.
  2. Connect a wire from the battery negative (-) to coil terminal 1; the solenoid should activate.
  3. If contacts are good, zero resistance should be read across the large terminals when coil is activated.
  4. Voltage drop across the contacts should never exceed one volt in circuit application.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Contact voltage drop never exceed one volt

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →