Home›Repair guides›Cummins/Onan›Battery Checkout

Cummins/Onan DL3 — Battery Checkout

Maintenance · Battery BT1

For the Cummins/Onan DL3, from the Cummins/Onan service manual.

Applies to: Cummins/Onan L Series Diesel engine

Before you start

  • Ignition of explosive battery gases can cause severe personal injury; no flame, spark, cigarette or other ignition source near the battery.

Procedure

  1. Check charge condition of battery with a hydrometer.
  2. Electrolyte specific gravity should be about 1.260 for a fully charged battery at 80°F (27°C).
  3. If not, add distilled water to keep electrolyte at proper level and recharge battery.
  4. If battery will not recharge, replace it.
  5. If battery state-of-charge is not maintained, charge rate may be too low; see Checkout [C].

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Electrolyte specific gravity about 1.260 at 80°F (27°C)

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.