Home›Repair guides›Cummins/Onan›Demand Regulator Test Procedure

Cummins/Onan — Demand Regulator Test Procedure

Testing & diagnosis

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan NHEL

Before you start

  • Most parts cleaning solvents are flammable and corrosive.

Procedure

  1. Connect pressure gauge to test port on back of regulator.
  2. Connect compressed air at least 80 psi (550 kPa) to inlet opening.
  3. If primary valve sound, gauge reads approximately 1-1/2 psi (10.3 kPa) and holds steady.
  4. Close air valve and observe gauge; pressure drop indicates secondary valve seat leaking.
  5. Disassemble and clean regulator if it fails either test; replace if still fails.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Cummins/Onan NHEL →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.