Cummins/Onan — Custom Battery Parameters
Adjustments · Battery charging parameters
From a Cummins/Onan owner's manual covering: 1.5HJBAA, 2.0HJBAA, 2.5HJBAA, 3.0HJBAA. Check it applies to your exact model before use.
Browse Cummins/Onan generators & specs →
Before you start
- Only trained and experienced persons may change BATTERY configuration parameters.
- Incorrect parameter settings can cause excessive battery gassing.
Procedure
- Press the INVERT ON / OFF button to disable Inverting.
- Select BATTERY on CONFIGURE INV. PG2 and press ENTER.
- On the BATTERY SETUP screen simultaneously press and hold both the + button and the - button for 5 seconds.
- On the CUSTOM BATTERY screen press NEXT to scroll between fields and the + / - buttons to change values.
- Press DONE to save the settings; the battery TYPE field will indicate CUSTOM.
- To restore the Onan preset configuration, pick Wet Cell, Gel #1, Gel #2, or AGM on the BATTERY SETUP screen.
Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.