Cummins/Onan TGHAA — Corrective Action:
For the Cummins/Onan TGHAA.
Applies to: Cummins Onan Tghaa
Before you start
- cooling capacity.)
Procedure
- 1. Replace Fuse F1 (B+) if blown.
- 2. Clean and tighten the positive (+) and negative (–) battery cable connections at the battery and at
- 3. Recharge or replace the battery. Refer to the battery manufacturer’s recommendations.
- 1. Reset or turn ON the line circuit breaker on the genset.
- 2. Reset or turn ON any other circuit breaker in the power supply system.
- 3. Check for proper transfer switch function.
- 1. Check for and remove any objects blocking the air inlet or outlet openings.
- 2. Reduce the electrical load. (Note that high altitude and high ambient temperature decrease engine
- 3. Clean the engine cooling fins and blower blades. See Periodic Maintenance.
- 4. Review the installation and housing design against the specifications and requirements of the Instal-
- 1. Check engine oil level and add oil as necessary. Repair oil leaks.
- 2. Drain excess oil. (Excess oil leads to foaming and a consequent loss of oil pressure.)
Source: manual:965-0101B Onan TGHAA Genset Operator manual.pdf. Figures and steps are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.