Home›Repair guides›Cummins/Onan›Contactor Closing Coil and Trip Coil Replacement (100-260 Ampere)

Cummins/Onan — Contactor Closing Coil and Trip Coil Replacement (100-260 Ampere)

Repair & overhaul · Contactor coil assembly

From a Cummins/Onan service manual covering: LT 100, LT 150, LT 200, LT 260, LT 30, LT 60. Check it applies to your exact model before use.

Applies to: Cummins/Onan TGHAA

Before you start

  • The closing coil and trip coil cannot be checked with an ohmmeter due to a rectifier circuit contained inside the sealed coil assembly.

Procedure

  1. Remove the transfer switch mounting bolts and move the assembly out until clearance for removing the coil assembly is obtained.
  2. Press in on the orange button on the side of the coil assembly and slide the assembly out of the contactor assembly.
  3. Reinstall by holding in the orange button while inserting the coil assembly into the contactor assembly.

Full service-parts list: Cummins/Onan TGHAA →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →