Home›Repair guides›Cummins/Onan›Configuring Battery at Inverter-Charger Front Panel

Cummins/Onan — Configuring Battery at Inverter-Charger Front Panel

Adjustments · Battery type configuration

From a Cummins/Onan owner's manual covering: 1.5HJBAA, 2.0HJBAA, 2.5HJBAA, 3.0HJBAA. Check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Press and hold the Inverter ON / OFF button for 5 seconds to check configuration; the three indicator lights turn ON and then flash the current battery type.
  2. Press the Charger ON / OFF button once to advance flashing to the next battery type (1 to 4 flashes).
  3. When the correct battery type is flashing, press the Inverter ON / OFF button once to save it.
  4. Enable Inverting and Charging to continue normal operation.

Specs & values

  • 1 flash = Wet Cell; 2 = Gel Type No. 1 (Standard); 3 = Gel Type No. 2 (Fast Charge); 4 = AGM

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.