Home›Repair guides›Cummins/Onan›Configuring Annunciator Lamps

Cummins/Onan — Configuring Annunciator Lamps

Adjustments · Status Lamps

From a Cummins/Onan service manual — check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Select Control button from left toolbar.
  2. Select Data (F9) from the bottom toolbar.
  3. Set the input nviMfgTest = 6 to turn all lamps on in their configured state.
  4. Under Inputs, scroll to nciLampConfig and select Modify (F2).
  5. Select lamp field and select Modify (F2).
  6. Enter the lamp number to configure lamps 1 ... 20 and press Done (F10).
  7. In the same manner, modify the color, horn, and flash fields as desired.
  8. Select Done (F10) to activate changes.
  9. After configuration, reset the node to resume normal operation.

Specs & values

  • lamp: 1 ... 20
  • color: GREEN, RED, AMBER
  • horn: OFF, ON
  • flash: OFF, ON (flashes lamp when activated, 1 Hz)

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.