Home›Repair guides›Cummins/Onan›Clean crankcase breather

Cummins/Onan — Clean crankcase breather

Maintenance

From a Cummins/Onan service manual covering: 10MJC, 15MJC, 3MJA, 4MJA, 5MJB, 705MJB. Check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Remove rubber cap from crankcase tube.
  2. Pry valve out of cap.
  3. Wash valve in fuel.
  4. Pull baffle out of breather tube and clean.
  5. Install valve with perforated disc toward engine.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.