Procedure

  1. Remove breaker box cover and check witness marks.
  2. Adjust breaker point gap to 0.020 inch at full separation.
  3. Turn flywheel until TC mark and gear cover mark align.
  4. Turn flywheel left until degree mark about two inches past mark.
  5. Turn flywheel slowly clockwise and check if points separate when degree mark aligns.
  6. Loosen breaker box mounting screws and shift assembly to advance or retard timing.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • 19° spark advance for 1500-2400 rpm
  • 25° spark advance for 2500 rpm and up
  • Breaker point gap 0.020 inch

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.