Home›Repair guides›Cummins/Onan›Oil Pressure Relief Valve Adjustment

Cummins/Onan CK-216E — Oil Pressure Relief Valve Adjustment

Adjustments

For the Cummins/Onan CK-216E, from the Cummins/Onan service manual.

Browse Cummins/Onan generators & specs →

Procedure

  1. Run plant until thoroughly warmed up.
  2. Loosen locknut and turn slotted stud in to increase pressure or out to decrease.
  3. Tighten locknut securely.

Specs & values

  • Oil pressure 25 to 40 pounds

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.