Cummins/Onan CK-216E — Magneto Stator Installation
Repair & overhaul
For the Cummins/Onan CK-216E, from the Cummins/Onan service manual.
Browse Cummins/Onan generators & specs →
Procedure
- Remove flywheel to expose stator.
- Use inside mounting holes for 19° spark advance.
- Use outside mounting holes for 25° spark advance.
- Connect small coil lead to cable clip terminal.
- Connect large lead to breaker box.
Specs & values
- 19° spark advance, inside holes
- 25° spark advance, outside holes
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.