Home›Repair guides›Cummins/Onan›Electric Choke Adjustment

Cummins/Onan CK-216E — Electric Choke Adjustment

Adjustments

For the Cummins/Onan CK-216E, from the Cummins/Onan service manual.

Browse Cummins/Onan generators & specs →

Procedure

  1. Check engine starting time; engine should fire in 6 to 15 seconds.
  2. If fires in less than 6 seconds, choke too rich; turn choke assembly clockwise for leaner.
  3. If not firing within 15 seconds, choke too lean; turn counterclockwise for richer.
  4. Loosen choke bracket mounting screw and rotate assembly as needed.

Specs & values

  • 58°F closed
  • 72°F half open
  • 82°F wide open

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →