Home›Repair guides›Cummins/Onan›Checking low-oil-pressure cut-off switch

Cummins/Onan — Checking low-oil-pressure cut-off switch

Testing & diagnosis

From a Cummins/Onan service manual — check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Procedure

  1. Throw MANUAL START-REMOTE START switch to MANUAL START and start the engine.
  2. If oil pressure does not build up normally, do not operate the engine until trouble is corrected.
  3. If oil pressure is normal but switch is suspected, disconnect wires from the switch.
  4. Throw switch to REMOTE START and start the engine electrically.
  5. If engine runs normally but stops when wires are connected, replace the cut-off switch.

Specs & values

  • Contacts open below 6 pounds per square inch

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.