From a Cummins/Onan service manual covering: GNH-250, GNH-XI0, GNHC4, GNVH450, GV12, GV12 series, GV12-525. Check it applies to your exact model before use.
Applies to: Cummins/Onan GV12
Procedure
- Check all pipes and fittings for leaks; tighten as necessary.
- Remove cover plate to drain pump.
- Lift out rubber impeller; check for cracks, breaks, damage.
- Clean out sediment; install new impeller if necessary.
- Install new cover plate gasket; use 0.015 inch gasket for proper clearance.
- Install cover on pump.
Specs & values
- 0.015 inch gasket
Full service-parts list: Cummins/Onan GV12 →
Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.