Home›Repair guides›Cummins/Onan›Charge Rate Adjustment

Cummins/Onan — Charge Rate Adjustment

Adjustments · Charging system

From a Cummins/Onan operator's manual covering: 12.0 DJC, 4.5 DJB, 4.5 DJE, 6.0 DJB, 6.0 DJE, 9.0 DJC. Check it applies to your exact model before use.

Browse Cummins/Onan generators & specs →

Before you start

  • Batteries present the hazard of explosion

Procedure

  1. Locate the adjustable resistor slide tap in the generator air outlet
  2. Move the slide tap to produce a 2 ampere charging rate
  3. Increase the charging rate slightly if frequent starts are required
  4. Adjust the slide tap only when the engine is stopped

Specs & values

  • 2 ampere charging rate

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →